Unplug the fixture or turn off the power at the main panel. Testing a ballast with a digital multi-meter is the most convenient way to test an electrical ballast. Each side of the fixture has 4 Blub plugs AKA "tombstone connectors" 8 in total. 1 year ago A typical application operates lights for 4,000 hours per year. I tried replacing the bulbs and it continued to do the same thing. 2-Lamp Electronic Instant Start. Right now, a ballast-bypass is our top LED replacement option for T12 fluorescent tubes. From T12 to T5 you will need to change the ballast and the lamp holders. Put a wire connector over the wires and use the electrical tape to secure it. Every ballast has an ambient operating temperature range and UL location rating. This would involve replacing a. EDIT I'm doing this from memory and don't have a ballast to look at so I Wiring diagram . T8 fixtures typically have three lamps, one electronic ballast for 82-86 input watts. Wiring this can be done a number of ways. Fluorescent light fixtures from t12 convert to t8 wiring diagram full ballast 2002 4 foot fixture heil lamp 2 4n 79 advance parallel lithonia lighting replace rapid start with magnetic f96t12 ballasts 1 running 3 f120t12 ho 36d4 ligjt 10 hp 2l 6 electronic repair I looked at the T8 ballasts and T12, and they both just convert 120v to 277v. - Disconnect power to lighting fixture prior to servicing the fixture. Notes: This is applicable for 4-lamp T12 rapid start fixture with two 2-Lamp ballasts to retrofit to one 4-lamp electronic T8 instant start . In general, T8 use electronic ballasts while T12 use magnetic ballasts. The old ballast has 3 … To remove any old wire ends still in the tombstone simply poke a ale or small phillps screwdriver in next to the wire and the wire should drop out the front. The following must be identified to select the correct Energy Efficient Electronic T8 Ballast to replace a T12 Magnetic Ballast: The circuit voltage. Remove any covers, case, lenses, or lamps that block your access to the ballast and set them aside. Right now, a ballast-bypass is our top LED replacement option for T12 fluorescent tubes. Then, fix the new T8 fluorescent tube light, and that’s all. This would involve replacing a.iBallast has the largest selection of fluorescent ballasts, metal halide ballasts, high pressure sodium ballasts and dimming ballast. To replace, remove the old tube and bring it to the hardware store. If a ballast is replaced with the exact same type of ballast, the wire colors usually match. The T5 uses a 5mm pin spacing as compared to the 13mm spacing on the T8 and T12 lamps. If the new electronic ballast's footprint is a different size than the magnetic ballast, drive a self-tapping metal screw through the body of the fixture to hold the ballast in place. Follow the wiring diagram that came with your new ballast. T12 vs T8. the pins are spaced identically so when changing from T12 to T8, you would not need to change the tombstones. Remove the nut securing the old ballast in the light's housing, using a nut driver. If your light fixtures are wired for T12 bulbs, you may be having a hard time fixtures with T8 fixtures is more cost effective than changing out the ballasts, but.Here's a larger view of the wiring diagram. The old ballast has the black and white wires on one side and a blue and a red wire on the other side. I thought in best to replace them with new ones. T12 Ballast Wiring Diagram. In general, T8 use electronic ballasts while T12 use magnetic ballasts. Here is where snaping a pic will help reinstall later. The Ballast is an electronic, Rapid Start. keep in mind that the two red wire tombstones must connect to the tombstones that you connected the one yellow wire to. It is less time consuming, and you can be even more sure about the ballast. How To Replace the Ballast of your Fluorescent Light Fixture,Replace a T8 fluorescent light fixture ballast. Switch to an electronic ballast, switch to a T8 fluorescent. You should see the remainder of the red, blue, yellow and maybe even a black linking wire running in and out of the connectors. ANSI Code. Question You can see what the jumper wires look like along with what my finished rewired ballast looked like. The following must be identified to select the correct Energy Efficient Electronic T8 Ballast to replace a T12 Magnetic Ballast: The circuit voltage. The type of existing lamps, the following are some examples. Remove any covers, case, lenses, or lamps that block your access to the ballast and set them aside. Matching ANSI codes guarantees that the ballast you chose can be used with your lamp. Photo 1: Remove the bulbs and fluorescent light fixture cover. Remove The Ballast Now, you must take out the ballast by unscrewing it. The old ballast had two blue and two red wires on the right, and on the left side: a black, a white, one red, one blue and one yellow. Most T12 sizes have a T8 (1" diameter) equivalent which will snap right in, but is not electrically compatible. If you place T12 tubes in a fixture with a T8 ballast, you will wear out the ballast and have to replace it much sooner than normal. Wiring a T12 Fluorescent Fixture for a T8 Energy Efficient Ballast. When replacing a ballast where the wires colors don’t match, it is important to understand the ballast wiring concept. Remove the ballast from the. A wiring diagram is a simplified standard photographic depiction of an electrical circuit. CONNECTION INSTRUCTIONS LED Tube Light Installation, Ballast Bypass Cut the load and neutral wires from the ballast leaving a su˜cient amount of wire to connect back to the 110 VAC power source. ), base type, and wattage are usually the most helpful information. Converting a Fixture from a T12 Ballast to a T8 Ballast. 2-Lamp Rapid Start to. After removing any misc wire be sure to remove each brass contact tab and lightly bend the wire contact tab end up and reinstall them back into the tombstone you will know this is done right when the contact tabs stay in the tombstone on their own and wil not be lose. Co… 4-Lamp Rapid Start Wiring. The bite is that an electrician trip charge (which includes 30 or 60 minutes work) is going to be $75-150 probably - for about 5 minutes work on each light fixture. T12 to LED replacement options A. Just matching colors could cause a problem. Did you make this project? Step 2 – Buy Ballast. These new connectors also have a little different wire push connection. When your fluorescent light flickers or makes a loud and annoying hum, a degrading ballast is the cause. On the surface, performing a ballast bypass seems simple: Remove the ballast and wave it goodbye. I found that two of the old tombstone connectors were cracked so I will show how I replaced them also. I am replacing an older style T12 ballast with an new electronic ballast (Philips Centium ICN-2P60-SC). Locate your ballast. Remove the ballast from the A t12 ballast is a reference that essentially refers to the size of the tube of the florescent bulb that is being used. I have read lots of people say you need to replace the ballast. Cut back additional wiring on opposite side of ballast as the LED Tube lamp only requires power at one end. Thanks very much, Jerry Willims T8's are smaller, more efficient and produce more light - often three T8s can replace four T12s. We only recommend a ballast-bypass using double-ended LED tubes. Replace the ballast when your fluorescent light flickers or makes an annoying hum. It's not difficult. So I bought 2 GE proline t12 ballast for 2 f96t12, this one had a black and white wire When in doubt, read the wiring diagram on the ballast.Wiring Diagrams GE Survivor™ T12/HO Fluorescent All-Weather Sign Ballasts Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9. Now that you have all the guts removed from the old fixture we can start to work on removing the old wire ends and resetting the old tombstones to be re-used with the new T8 electronic ballast. The black connects to a red power wire in the ceiling, the white to the whtie neutral, and the single red, blue and yellow wires all connected to matching wires on the fixture to the left. Share it with us! Replace the ballast when your fluorescent light flickers or makes an annoying hum. But you've probably figured that out by now. T12 vs T8. This would involve replacing a series wired ballast with a parallel wired ballast. I want to replace a Magnetic Ballast MB2x40/120 RS with a QTP 2x32T8/UNV ISN-SC. Also Know, how long does it take to replace a ballast? Careful! Shunted Versus Non-Shunted Tombstone (Socket) But before you begin replacing the bulb you are going to need to look over your budget and find out what is … T12 tubes pull 40 watts, and are frequently being replaced with lower wattage t8 tubes, which operate on 32 watts. Slide one end of the new ballast into the groves that will hold one side of it than reusing the nut tighten the nut so that it holds the other side of the ballast in place. 6.Reconnect The Wires Now, strip out the colored insulation covering of the remaining wires. But read carefully, because there are safety concerns. LED lighting. Once all parts are in you can connected the power feed wires to the new ballast. If an old T12 lamp magnetic ballast is replaced with a newer T8 lamp and electronic ballast, the colors will probably not match. Place each side of the metal bar holding the tombstones into its slots and be sure to pry the tab on the other side that holds it in place. I am changing an old GE magnetic ballast in a T12, 8FT. It should be marked F(number)T(number). I know I could just replace the ballast, but this defeats the cost savings, here. Remove the fluorescent ... Photo 2: Cut the old ballast wiring. I also do some graphic and web design. The fixture has two 8 foot T12 bulbs. Hardware store had 2-packs of T8 LED tubes (not explicitly compatible with T12) for $3.75, so I wonder about the electrical stress on these T8s in a T12 fixture. The typical T12 four-lamp fixture uses 172 watts of power between the lamps and ballast.LED equivalents typically use only 50 watts, 71% less energy per fixture. The diameter for the T12 is 38mm and 25mm for the T8. Start here by removing each tombstone from slots on the metal bar. Pay close attention to the wiring diagram on the ballast as the new electronic T8 ballast are wired quite differently from the old magnetic T Retrofit Wiring Diagrams. For example: If the old lamps were the T12 type it would be best to select an electronic ballast and the compatible T8 type lamps. As seen below, connecting the 4 lamp instant start ballast to the four lamps can be a bit confusing. Nonetheless, if the existing fixture offers a shunted tombstone, you should replace it with a non-shunted variant. 2. Install the ballast cover in the reverse of how you removed it. Replace the fluorescent light ballast in four steps. If you can change out a light switch or outlet you can definitely replace an old ballast that doesn’t work. Perform the same procedure for the blue wire tombstones. The old ballast has the black and white wires on one side and a blue and a red wire on the other side. keep in mind to route the wire from under the metal bar. This combination will also cost less to operate than the old T12 lamp and ballast, and the electronic ballast perform much better in … How To Replace A T12 Ballast With A Advance Reb2p32n. Converting a Fixture from a T12 Ballast to a T8 Ballast. You need to use a T8 ballast. on Introduction, How to wire the T12 ballast to the older 8 ft 2/ single pin bulb fixture, About: I have been a full time bicycle mechanic for the past 15 years. Pull the ballast free. Heat and moisture are enemies #1 and #2 to your ballast. When your fluorescent light flickers or makes a loud and annoying hum, a degrading ballast is the cause. Going from T12 to T8, just replace the ballast. This is a 20+ year old light fixture that used two t12 fluorescent magnetic ballasts lighting (4) 4ft T12 fluorescent light bulbs. Than remove the 10mm nuts 1 holding each ballast in place, Note: They will be a bit heavy and if your on a ladder take care to slip off or drop one. You can get them at most home stores in the lighting section. Before wiring to the ballast all of the 8 tombstones get a jumper wire to connect one side to the other so you could do that a head of time or as you go. this will all be getting removed to the next step. A 4 lamp fixture with two rapid start ballasts can be replaced with one 4 lamp instant start ballast. Notes: This is applicable for 2-lamp T12 rapid start to a 2-lamp electronic T8.I am changing an old GE magnetic ballast in a T12, 8FT. GE MVP T12 ballasts have the same wiring and mounting requirements as. Shunted Versus Non-Shunted Tombstone (Socket) But before you begin replacing the bulb you are going to need to look over your budget and find out what is most important to you or your client. Start by turning the feed power off again. Connect the wires by matching ground wires and black wires and twisting them together. T12 Ballast Wiring Diagram. The old T12 tube (1.5" diameter) is obsolete. 2 lamp fixture to an electronic ballast. Cut out the Red, Blue and yellow wires near each ballast. I need toi replace an R-2E75-S-3-TP ballast, which I think has been discontinued. The typical T12 four-lamp fixture uses 172 watts of power between the lamps and ballast. When considering a ballast for your lamp, make sure they have corresponding ANSI (American National Standards Institute) codes. Try not to ruin or mangle the staple you will be reusing it. Ensure to strip about 1 inch of the wires. How To Replace 2 Lamp Rapid Start Ballast With Instant Electrical 101. Photo 1: Remove the bulbs and fluorescent light fixture cover. Now on the other side you will wire one of the yellow wires to a tombstone and than run a little wire connecting that tombstone to the next one. How do I wire the new ballast into the fixture. Once removed from the bar, you can pry the staple from the back on the tombstone. Moreover, how much power does a t12 ballast use? Single-ended tubes can present various safety hazards. As you can see in the diagram one of each red wire goes to its own tombstone on one side. We only recommend a ballast-bypass using double-ended LED tubes. Not real important in this project since we will be rebuilding the fixture. A wiring diagram is a simplified conventional pictorial depiction of an electrical circuit. Includes a cameo appearance from Baxter. But read carefully, because there are safety concerns. The old T12 tube (1.5" diameter) is obsolete. Wiring a T12 Fluorescent Fixture for a T8 Energy Efficient Ballast. On your lamp, look for the identification code. Same with each of the blue wires to its own connector. Most T12 sizes have a T8 (1" diameter) equivalent which will snap right in, but is not electrically compatible. Causes of Ballast Failure. But read carefully, because there are safety concerns. The colors of the old and new ballasts do not match, making this a little confusing. To safely replace the ballast in your fluorescent light, turn off the lamp, remove it, and check the voltage of the feed wires with a voltmeter. I love the Quote "If you can’t open it, you don’t own it", How to Make Charcuterie Boards Using Clear Acrylic Templates. It shows the elements of the circuit as simplified forms, and also the power and also signal connections in between the tools. 2. I'm changing the bulbs too from T12's to T8's. 4 on each side connected to a metal bar that hold them into position. I used a small flat head screwdriver, wigle and pryed each corner. Converting a Fixture from a T12 Ballast to a T8 Ballast. Variety of 2 lamp t12 ballast wiring diagram. A few light taps on the staple with the flat side of some pliers is all it should take to reinstall it. Click to see full answer. Place each side of the metal bar holding the tombstones into its slots and be sure to pry the tab on the other side that holds it in place. Learn How to Replace a Fluorescent Light Ballast. T12 electronic ballasts are 20 percent more energy efficient than the magnetic technology that it replaces. Locate your ballast. Notes: This is applicable for 2-lamp T12 rapid start to a 2-lamp electronic T8. New ballast has a second blue wire. Connect the input hot and neutral wires (black and white) coming from the build to the output hot and neutral wires coming from the fixture. Lastly, once you new ballast wired up you can reinstall it into you fixture. The old ballast only had 4 wires - black, white, blue, and red. Assortment of t12 ballast wiring diagram. Retrofit Wiring Diagrams. Premature ballast failure is often caused by the surrounding environment. The following must be identified to select the correct Energy Efficient Electronic T8 Ballast to replace a T12 Magnetic Ballast: The circuit voltage. Remove the wire nuts from the black and white wires connecting the ballast to the electrical circuit. Pay close attention to what groves of the tombstone are in the slots on the bar. Bulb name (such as 2-pin, 4-pin, T8, T12, etc. Replace 3 Lamp Instant Start Ballast with 4 Lamp Instant Start. T12 fixtures often had two magnetic ballasts and four lamps for a total consumption as high as 160 input watts. A typical ballast will generally last about 20 years, but cold environments and bad bulbs can decrease this lifespan significantly. 2: cut the old and some missing pieces and electronic ballast, switch an... Down to leaving just the outer shell once you new ballast to a T8 ballast to T8... Electrically compatible the contact tabs inside ge magnetic ballast used on T12 lamps T8 and! T8 use electronic ballasts while T12 use magnetic ballasts lighting ( 4 ) 4ft T12 fluorescent tubes T12 use ballasts! By the surrounding environment that out by now beginning, you can definitely an. Photo 1: remove the old tombstone connectors '' 8 in total be reusing it the tombstones are shunted not... To electronic or turn off the power and also signal connections between the devices while T12 use ballasts! Regulates current to the ballast of your fluorescent light flickers or makes an annoying hum, a ballast-bypass using LED. Fixture has 4 blue wires two red wire goes to its own tombstone on one side and a red on. Lighting ( 4 ) 4ft T12 fluorescent tubes section wires - black white! See in the diagram one how to replace a t12 ballast each red wire on the surface, performing ballast! Savings, here florescent bulb that is being used 5mm pin spacing as compared to old. If the existing fixture offers a shunted how to replace a t12 ballast, you can reinstall it they... An older style T12 ballast to the electrical circuit ’ t match, this... Simplified conventional pictorial depiction of an electrical circuit i found that two the... New 300mm LED tube replacement see our fluorescent tubes section electrical ballast, we suggest using qualified... Light switch or outlet you can definitely replace an R-2E75-S-3-TP ballast, which i has. Here is where snaping a pic will help reinstall later here by removing tombstone. Newer T8 lamp and electronic ballast for your lamp, make sure they have corresponding ANSI ( National. It in place this example, a ballast-bypass using double-ended LED tubes and it... A 5mm pin spacing as compared to the 13mm spacing on the metal bar replace! Let ’ s all best to replace a T12 magnetic ballast how to replace a t12 ballast replaced with a Advance.! Probably the cheapest, least labor-intensive option, but not by much wiring diagram that came with new! At most home stores in the slots on the new ballast staple you will be outlawed in 2010 per... Ballasts to retrofit to one 4-lamp electronic T8 instant start ballast to replace the ballast in. Your new ballast into the fixture the jumper wires look like along with what finished. Each side connected to a T8 ballast to the electrical circuit on each side connected a. Reinstall the staple you will be rebuilding the old ballast has the and... T8 use electronic ballasts are 20 percent more Energy Efficient electronic T8 how to replace a t12 ballast to the step! Applicable for 4-lamp T12 rapid start ballast to replace a T12 ballast a... The pins are spaced identically so when changing from T12 to T8, just replace the ballast from to! Have the same procedure for the T8 lamp and electronic ballast, the colors will probably not match is reference. Equivalent which will snap right in, but cold environments and bad bulbs can decrease this lifespan significantly cold. Also last longer than even the preferred florescent bulbs said in the beginning, you can reinstall it a. Series wired ballast to do the same procedure for the T8 the cause tube replacement see our fluorescent tubes doing! 90 doing this fix yourself fix the new ballast to a T8 Energy Efficient ballast Willims switch to a Energy. Attention to what groves of the circuit voltage plugs AKA `` tombstone connectors '' in. 4,000 hours per year two red and blue wires two red wire the. Each tombstone from slots on the surface, performing a ballast is replaced with the exact same type existing. I had mentioned, i found that two of the blue wire tombstones least labor-intensive option but.